QC1 Plotter

xshooter_tell_mf: telluric standard star molecfit parameters (details)

QC HOME QC1 DB BROWSE HELP

 

Select for plotting:


1. Plot Items
X axis Y axis Item Comment
mjd_obs MJD-OBS of (first) raw file
ambient_temp ambient temperature (C degrees)
cryo_temp cryostat temperature (C degrees)
counts1 average counts in first region (ADU)
err1 error of the average counts in first region (ADU)
sn1 average signal-to-noise ratio in first region
counts2 average counts in second region (ADU)
err2 error of the average counts in second region (ADU)
sn2 average signal-to-noise ratio in second region
counts3 average counts in third region (ADU)
err3 error of the average counts in third region (ADU)
sn3 average signal-to-noise ratio in third region
npix_high (maximum) number of pixels above 60000 ADU (UVB/VIS) in raw frame(s)
npix_sat number of saturated pixels in raw frame(s)
fpix_sat fraction of saturated pixels in raw frame(s)
slit_width slit width in arcsec
airmass average airmass
image_quality_tel average image quality (TEL.IA.FWHM)
IWV average integrated water vapor from radiometer
MF_status molecfit process stutus
MF_NumFitParam molecfit Number of fit parameters
MF_NumWeightGZ molecfit Number of Pix with weight>0
MF_FracValModPix molecfit Fraction of valid pixel
MF_Iterations molecfit Number of Iterations
MF_LBLRTM_calls molecfit Number LBLRTM calls
MF_Initial_chi2 molecfit initial chi2
MF_Best_chi2 molecfit best chi2
MF_Reduced_chi2 molecfit reducec chi2
MF_RMS_error molecfit RMS relative to error
MF_RMS_mean molecfit RMS relative to mean
MF_FWHM_boxcar molecfit FWHM boxcar in pixel
MF_FWHM_Gaussian molecfit FWHM Gaussian in pixel
MF_FWHM_Lorentzian molecfit FWHM Lorentzian in pixel
MF_WL_coef0 molecfit wavelength coef0
MF_WL_coef1 molecfit wavelength coef1
MF_H2O_rmgc molecfit H2O rel mol gas col
MF_CO2_rmgc molecfit CO2 rel mol gas col
MF_CO_rmgc molecfit CO rel mol gas col
MF_CH4_rmgc molecfit CH4 rel mol gas col
MF_O2_rmgc molecfit O2 rel mol gas col
MF_H2O_PPMV molecfit H2O mol gas col in PPMV
MF_CO2_PPMV molecfit CO2 mol gas col in PPMV
MF_CO_PPMV molecfit CO mol gas col in PPMV
MF_CH4_PPMV molecfit CH4 mol gas col in PPMV
MF_O2_PPMV molecfit O2 mol gas col in PPMV
MF_H2O_mm molecfit H2O in mm
ADC_y0 2D product spectrum center
ADC_y1 2D product spectrum slope
ADC_y2 2D product spectrum quad
ADC_x0 2D product central pixel x
ADC_failure ADC.ENCSTART check

2. Filter by
target_name name of standard star
arm arm
clock readout (speed, ports, gain, binning)
binx binning in X direction
biny binning in Y direction
chip_id detector ID
obs_mode Observing mode (IFU or SLOT)
slit slit
exptime exposure time
dit DIT
ndit number of DITs
mode pipeline mode (physical model or polynomial fit)
pipe_vers pipeline version
process_scheme processing scheme
start1 start wavelength of first region in nm
end1 end wavelength of first region in nm
start2 start wavelength of second region in nm
end2 end wavelength of second region in nm
start3 start wavelength of third region in nm
end3 end wavelength of third region in nm
MF_version molecfit processing version
QC_version QC script version

3. Options
time range:
for plot: From To
for statistics: From To
plot options:
y scaling for plotting: y_min y_max
x scaling for plotting: x_min x_max
special:
connect by lines mark outliers civil_dates
plot format: png gif ps
statistics options:
average none mean median least-square
error thresholds none 1 sigma 3 sigma 10%


Send comments to: <qc@eso.org>