QC1 Plotter

xshooter_night_ifu: IFU science and standard star qc1 parameters (details)

QC HOME QC1 DB BROWSE HELP

 

Select for plotting:


1. Plot Items
X axis Y axis Item Comment
mjd_obs MJD-OBS of (first) raw file
ambient_temp ambient temperature (C degrees)
cryo_temp cryostat temperature (C degrees)
counts1 average counts in slice 1
counts2 average counts in slice 2
counts3 average counts in slice 3
min_12 minimum difference between traces in slice 1 and 2
max_12 maximum difference between traces in slice 1 and 2
avg_12 mean difference between traces in slice 1 and 2
med_12 median difference between traces in slice 1 and 2
rms_12 rms of difference between traces in slice 1 and 2
min_13 minimum difference between traces in slice 1 and 3
max_13 maximum difference between traces in slice 1 and 3
avg_13 mean difference between traces in slice 1 and 3
med_13 median difference between traces in slice 1 and 3
rms_13 rms of difference between traces in slice 1 and 3
min_32 minimum difference between traces in slice 3 and 2
max_32 maximum difference between traces in slice 3 and 2
avg_32 mean difference between traces in slice 3 and 2
med_32 median difference between traces in slice 3 and 2
rms_32 rms of difference between traces in slice 3 and 2
npix_high (maximum) number of pixels above 60000 ADU (UVB/VIS) in raw frame(s)
npix_sat number of saturated pixels in raw frame(s)
fpix_sat fraction of saturated pixels in raw frame(s)
airmass average airmass
iq_tel Average image quality as delivered by active optics to instrument (arcsec, keyword TEL.IA.FWHM, airmass correction undone!)
iq_tel_rms rms of image quality as delivered by active optics to instrument (arcsec, keyword TEL.IA.FWHM, airmass correction undone!)
iq_tel_rms_rel relative rms of image quality as delivered by active optics to instrument (arcsec, keyword TEL.IA.FWHM)
dimm Average image quality as measured by the DIMM (arcsec)
dimm_corr Average image quality as measured by the DIMM (arcsec) corrected to airmass and wavelength of observation

2. Filter by
target_name name of target
arm arm
clock readout (speed, ports, gain, binning)
binx binning in X direction
biny binning in Y direction
chip_id detector ID
obs_mode Observing mode (STARE, OFFSET, or NODDING)
slit slit
exptime exposure time
dit DIT
ndit number of DITs
mode pipeline mode (physical model or polynomial fit)

3. Options
time range:
for plot: From To
for statistics: From To
plot options:
y scaling for plotting: y_min y_max
x scaling for plotting: x_min x_max
special:
connect by lines mark outliers civil_dates
plot format: png gif ps
statistics options:
average none mean median least-square
error thresholds none 1 sigma 3 sigma 10%


Send comments to: <qc@eso.org>